These Standards provide guidelines for Residential
Home Inspectors. The guidelines
outline what the Home Inspector should observe,
identify, inspect and describe.
They also provide the minimum contents of a written report.
These guidelines are not intended
to limit the Residential Home Inspector. The Inspector may provide additional inspection
services that are not covered in the Standards if they choose to do so.
Systems or components that are not inspected, identified or reported (limitations or exclusions)
can be found after each section.
Introduction:
The purpose of the Residential Standards of Practice (Standards)
is to establish a uniform guide
for performing an inspection of buildings and equipment. Terms:
A glossary of terms and definitions
is located in back of the Residential Standards.
Procedures:
The procedures are the Residential Standards that identify
what is to be inspected and reported.
The Inspector will not disclose and information concerning
the results of the inspection without the
approval of the clients or their representatives.
The Inspector will not accept compensation, financial or otherwise,
from more than one interested
party for the same service without the consent of all interested
parties.
The Inspector will not accept, or offer commissions or allowances,
directly or indirectly, from
other parties in connection with work for which the Inspector
is responsible.
The Inspector will promptly disclose to the client any interest
in a business which may affect the client.
The Inspector will not allow an interest in any business to
affect the quality or results of the inspection
work, which the inspector may be called upon to perform.
The Inspector may not perform any work or improvement to a
residence upon which the Inspector
performed a home inspection within the previous 12 months.
Back to top
Purpose:
The purpose of a residential inspection is to disclose the
general conditions of the building,
improvements, mechanical systems and appliances as they exist
on the day of the inspection.
Scope:
The scope of the residential inspection is a visual observation,
with limited use of mechanical instruments,
of readily accessible areas of the building, improvements,
mechanical systems and appliances.
The inspection is limited to areas and systems identified as
follows: grounds and appurtenances;
roofing/guttering/other roof components; home exteriors; garage/carport;
electrical basement/
crawl space/slab; plumbing; heating; cooling; attic; and general
interiors and kitchen/appliances.
Back to top
Limitations:
The Residential Inspector Standards are designed to identify
and disclose observed general conditions.
The residential inspections limited to readily accessible areas.
No disassembly of equipment or
activating of equipment that has bee "shut-down" should
be performed. No opening of walls, moving
of furniture, appliances, stored items, walking on roofs or
excavation is to be performed. Concealed,
camouflaged or inaccessible conditions may not be exposed.
Systems and conditions that are not
within the scope of the inspection include, but are not limited
to: environmental hazards (e.g. lead
paint, formaldehyde, toxic of flammable materials, asbestos,
radon); pest infestation; portable appliances
(e.g. washer, dryers, window air conditioner); security systems;
telephone or television systems, fire or
lawn sprinklers; swimming pools; spas or jetted tubs; tennis
courts; playground or other recreational
or leisure appliances or equipment; below ground septic or
drainage systems; water wells; zoning
ordinances; or any items considered cosmetic in nature. Any
general comments about these systems
and conditions are informational only and do not represent
an inspection.
Back to top
Warranties and Guarantees:
The residential inspection report is not intended to be used
as a guarantee or warranty, expressed or
implied, regarding adequacy, performance, or condition of any
inspected building improvements,
mechanical system or appliance. The residential Inspector should
take no position on value nor make
any representation as to advisability of purchase or suitability
to use. The Inspector should not incite
or stir up quarrels or groundless lawsuits.
Licensing Requirements:
License Requirements for Persons Engaging in the Business
of Inspection Practice: A state license is
required for anyone offering or practicing home inspection
unless that individual is a currently licensed
engineer, architect, general contractor or residential builder.
This requirement is based on
Chapter 106, Statutory Authority: 1976 Code § 40-59-210
- 40-59-240(B).
Back to top
A) Roofing, Guttering and Other Roof
Components
1. Roof Style
A. Identify and report the styles of roofs. (Examples: hip,
gable, shed, mansard, etc.)
2. Roof Coverings (materials)
A. Identify the type materials (composition shingles, slate,
cement asbestos, etc.).
B. Inspect the covering and report the observed condition,
describing visible condition and evidence of leaks.
3. Visible Flashing:
A. Inspect and report the observed condition of visible
flashing. If flashings
are not visible report not visible, not inspected.
4. Skylights:
A. Report if present or not.
B. Inspect and report if there is evidence of leaking.
5. Roof Penetrations (plumbing stacks, gas vents, etc.):
A. Inspect and report the observed condition of all roof
protrusions and their flashing.
B. Describe and report defects or deficiencies.
6. Fireplace Chimneys:
A. Report if present or not.
B. Inspect and report the observed condition of the chimney
and its component elements.
C. Describe and report defects and/or deficiencies
7. Gutters and Downspouts:
A. Report if present or not.
B. Inspect and report the observed conditions of the gutters
and downspout systems.
C. Describe and report defects or deficiencies.
Limitations. The Inspector is not required to:
A. Perform tasks that place his or her person in danger.
B. Inspect or report on accessory items not listed above
(antennas, solar panels, etc.).
C. Estimate the remaining life of the roof coverings, flashing,
caulking materials or other components.
D. Handle or disturb materials suspected of containing hazardous
materials.
Note: Describe and report how the roof was inspected (from
ground, with binoculars, from a ladder).
Note: Describe and report areas that could not be inspected
(top of flat roof, valleys of compound roof designs, etc.).
Back to top
B) Exterior
1. Trim:
A . Inspect and report the observed condition of the materials.
B. Describe and report defects.
2. Siding/Wall Coverings:
A. Identify the materials by type.
B. Inspect and report the observed condition.
3. Paint:
A. Inspect and report the the observed condition.
B. Observe the condition of paint and caulking.
4. Windows:
A. Inspect and report the observed condition of a representative
number.
B. Identify and report the type (wood, metal, etc.).
C. Describe and report defects or deficiencies.
5. Doors:
A. Inspect and report the observed condition of all accessible
exterior doors.
B. Describe and report visible defects.
6. Storm Windows and Doors:
A. Report if present or not.
B. Describe and report visible defects.
7. Screens:
A. Report if present or not.
B. Report the observed condition.
8. Porches:
A. Report if present or not.
B. Inspect and report defects or deficiencies.
9. Decks, Patios and Balconies (attached to dwelling):
A. Report if present or not.
B. Inspect and report the observed condition of the structures
and components.
C. Describe and report defects and/or deficiencies.
10. Alterations:
A. If determinable, report if alterations or additions
have been made to original house.
Back to top
C) Garage/Carport:
1. Type:
A. Report if present or not.
B. Describe style, size and location. (Example: two-car attached
garage or carport, single
car attached, two car drive under, etc.)
2. Doors and Openers:
A. Report if present or not.
B. Operate doors and/or openers and report if functional.
3. Limitations:
A. The inspector is not required to:
1. Operate door openers that have been disconnected from
power source.
2. Operate doors if animals are loose in a garage.
Back to top
D) Electrical
1. Over Current Protection:
A. Identify and report the type.
B. Inspect and report the visible condition.
C. Describe and report defects and/or deficiencies.
2. Type Conductors, Main and Branch Circuits:
A. Identify the type conductors present on the service
cable and all visible circuit conductors
(aluminum or cooper).
B. Describe and report visible defects and/or deficiencies.
C. Report the location of the main service panel and sub-service
panels.
3. Incoming Service:
A. Identify and report the location (overhead or underground).
B. Describe and report the condition.
4. Grounding Cable:
A. Identify and report the presence, location and observed
condition of grounding
conductors.
5. Fixtures and Outlets:
A. Test a representative number of accessible light switches,
wall receptacles and
light fixtures.
B. Describe and report defects and/or deficiencies.
C. Identify and report the presence of aluminum wiring in
Brach circuit conductors.
6. Ground Fault Circuit Interruptor (GFCI):
A. Report if present or not.
B. Identify the location of GFCI breakers.
C. Test and report if breakers that protect wall outlets
are operational or inoperable.
Describe how tested.
7. Smoke Detectors:
A. Report if present or not.
Limitations
A. Inspector is not required to:
1. Insert any tool, probe or testing device into the
main or sub-panels.
2. Activate electrical system or branch circuits that are
not energized.
3. Operate overload protection devices except GFCI breakers.
4. Test GFCI breakers that are not connected to a wall
outlet.
5. Move objects to gain access to electrical outlets or
panels.
6. Inspect equipment that is not readily accessible, nor
dismantle equipment or component.
7. Test all switches, receptacles, or fixtures, not to
remove switch or receptacle.
8. Operate a smoke detector by any means other than supplied
by the manufacturer.
Back to top
E) Basement, Crawl Space, Slab
1. Basement:
A. Report if present or not.
2. Crawl Space:
A. Report if present or not.
B. Report if not entered and/or how inspected.
C. Inspect and report entry access location, and adequacy
of under-floor ventilation.
D. Describe and report any visible damage.
3. Slab:
A. Report if present or not.
B. Inspect and report visible conditions.
C. Describe and report visible defects and/or deficiencies.
4. Visible Framing:
A. Report if not visible.
B. Inspect and report the observed condition of the visible
materials and structural components.
C. Describe and report defects and/or deficiencies.
5. Visible Foundation Walls:
A. Report the type materials.
B. Inspect and report observed condition of the visible materials.
C. Report if walls are not visible.
D. Describe and report defects and/or deficiencies.
6. Floors:
A. Report the type materials (concrete, dirt or wood).
B. Inspect and report the observed condition.
C. Describe and report defects and/or deficiencies.
7. Sump and Pump:
A. Report if present.
Limitations
A. The inspector is not required to:
1. Enter crawl space with headroom less than 18 inches
or where adverse conditions exist.
2. Move stored items or debris.
3. Enter areas that may contain hazardous materials.
4. Determine the extent of damage cased by insects or water.
Back to top
F) Plumbing
1. Visible Water Piping:
A. Identify and report the type.
B. Describe and report defects and /or deficiencies.
2. Visible Waste Piping:
A. Identify and report the type.
B. Describe and report defects/and or deficiencies.
3. Water Supply:
A. Identify and report the source.
B. If source is unknown, report as unknown.
C. Verify presence of back flow prevention device.
4. Waste Disposal System:
A. Identify and report the source.
B. If source is unknown, report as unknown.
C. Describe and report defects and/or deficiencies.
5. Main Water Shut-Off:
A. Report the location.
6. Water Heater:
A. Identify and report the observed condition.
B. Determine if pressure relief valve is present.
7. Faucets:
A. Report functional flow.
8. Drains:
A. Report functional drainage.
9. Water Pressure:
A. Report adequacy.
10. Showers and all Fixtures:
A. Operate all fixtures.
B. Inspect and report the observed condition.
C. Describe and report defects and or deficiencies.
11. Washer and Dryer Connections:
A. Inspect and report location.
12. Other Equipment:
A. Inspect and report the observed condition of waste ejection
systems when possible.
B. Inspect and report the presence and condition of laundry
tubs and wet bars.
C. Describe or identify other equipment and report if tested
or not tested.
Limitations
A. The Inspector is not required to:
1. Operate systems that have been "shut down" or
winterized.
2. Operate pressure relief valves where the Inspector feels
operation may result in leaking.
Back to top
G) Heating
1. Type Energy Source
A. Report type of fuel.
2. Equipment:
A. Report the type equipment.
B. Operate and report the observed condition of thermostat.
3. Btu/hr Rating:
A. Report the Btu/hr rating, if available.
4. Location and Condition:
A. Report the location of all heating equipment.
B. Operate, inspect and report the observed condition.
C. Describe and report defects and/or deficiencies.
5. Distribution:
A. Inspect and report the observed condition of the visible
supply and return air ducts return openings.
6. Vents:
A. Inspect and report the observed condition of a representative
number of supply and return openings.
7. Filters:
A. Identify if present.
8. Other:
A. Inspect and report the presence and observed condition
of fixed units used for supplementary heating.
Limitations
A. The Inspector is not required to:
1. Operate equipment when the exterior temperature is 85 degrees
Fahrenheit or above.
2. Activate equipment that has been "shut down" or
will not respond to thermostat controls.
3. Disassemble equipment by any means other than panels provided
by the manufacturer for
inspections and/or service.
4. Report on the efficiency of the system or distribution.
Back to top
H) Cooling:
1. Type Energy Source:
A. Report the energy source.
2. Equipment Brand:
A. Report the type equipment by brand.
3. Btu/hr Rating:
A. Report the Btu/hr rating, if available.
4. Condition and Operation:
A. Operate the equipment (weather permitting) by normal
control services and report the
observed condition.
Limitations
A. The Inspector is not required to:
1. Activate systems that have been "shut down" or
otherwise deactivated.
2. Operate cooling equipment when the ambient temperature has
been less than 65 degrees
Fahrenheit within the previous 24 hours.
3. Report on the efficiency of the equipment.
Back to top
I) Attic
1. Access:
A. Report if not entered and why.
2. Insulation Type and Approximate Depth:
A. Identify and report the type and approximate density
of thickness of the insulation.
3. Ventilator Fan:
A. Identify if present and report observed condition.
4. Whole House Fan:
A. Identify if present and report observed condition.
5. Framing:
A. Identify and report defects and/or deficiencies.
6. Leaks:
A. Identify and report evidence of leaking, both previous
and existing.
Limitations
A. The Inspector is not required to:
1. Enter attic spaces where the headroom is less than 3 feet.
2. Enter attic spaces where hazardous conditions exist.
3. Evaluate ventilation adequacy by any means other than visually.
4. Evaluate the efficiency of insulation other than by accepted
thickness.
Back to top
J) General Interior
1. Walls:
A. Report the observed conditions.
2. Ceilings:
A. Report the observed conditions.
3. Floors and Floor Coverings
A. Report the observed conditions.
4. Stairs:
A. Identify if present.
B. Report the observed conditions.
5. Doors:
A. Operate all accessible doors.
B. Report the observed conditions.
6. Windows:
A. Operate a representative number of windows and at least
one window in each
designated sleeping area.
B. Report the observed conditions.
7. Fireplaces:
A. Identify, if present, and report the observed condition.
Limitations:
A. The Inspector is not required to:
1. Move furniture or owner's possessions.
2. Light a fire in the fireplace.
Back to top
K) Kitchens and Appliances
1. Identify fuel source.
A. Observe and report all built-in appliances
2. Cabinets:
A. Report the observed condition.
3. Stove or Range:
A. Identify fuel source.
B. Operate and report defects and/or deficiencies.
4. Oven:
A. Identify fuel source.
B. Operate and report defects and/or deficiencies.
5. Trash Disposal
A. Identify if present.
B. Operate and report defects and/or deficiencies.
6. Fan/Vent Hood:
A. Identify if present.
B. Operate and report defects and/or deficiencies.
7. Dishwasher:
A. Identify if present.
B. Operate and report defects and/or deficiencies.
Limitations
A. The inspector is not required to:
1. Calibrate temperatures to determine if the oven-heated temperature
corresponds
to the control setting.
2. Determine the efficiency of any equipment.
3. Determine the remaining life of any equipment.
Back to top
L) General Conditions of Residence
1. Report general condition of the residence and the maintenance.
M) Advertisements
1. For the purpose of this section, advertisements include,
but are not limited to, inspection reports, business
cards, invoices, signs, purchased telephone directory displays
and advertising by newspapers, radio and
television.
A. Advertisements by a person licensed as an Inspector should
contain the Inspector's name, the
business name, address and license number of the Inspector.
B. The Commissioner may reprimand, suspend or revoke the license
of a person who is found
to have engaged in false or misleading advertising or to have
failed to comply with provisions
of this section.
C. Any Inspector who moves is required to keep the Commission
informed of any change of address.
Back to top
N) Departure Provision
An Inspector should exclude from the inspection any part,
component or system which the inspector
is not competent or qualified to inspect.
Any exclusion should be disclosed in the report.
Glossary of Terms
For the purpose of the Residential Standards, certain abbreviations,
terms, phrases, words and their
derivatives shall be construed as defined in this Glossary
of Terms. Words used in the present tense
include the future. Words, terms or phrases not defined below
will have the meanings stated in the Standard
Building Code, Standard Mechanical Code, CABO One and Two Family
Dwelling, Standard Plumbing
Code, Standard Gas Code and National Electric Code. Words not
defined below or in one of the Codes
will have the meanings in Webster's Ninth New Collegiate Dictionary,
as revised.
- ACTIVATE:
- To turn on equipment by normal control means such
as a thermostat or control switch.
- ACCEPTABLE:
- Functioning as designed, installed or intended.
- ACCESSIBLE:
- Admitting close approach, but which first may require
the removal of a panel, door or similar
covering of the item described, without damaging the building
structure or finish. See READILY ACCESSIBLE.
- ACCESSORY BUILDING:
- A secondary building, the use of which
is incidental to that of the main building.
- ADEQUATE OR ADEQUACY:
- Equal to a requirement, sufficient.
- AMBIENT TEMPERATURE:
- The temperature around equipment.
- ATTIC:
- Accessible space between top of uppermost ceiling and
the underside of roof. Inaccessible spaces
are considered structural cavities.
- BASEMENT:
- A space of full story height below the first floor
wholly or partly below exterior grade.
- CELLAR:
- That portion of a building, the ceiling of which is
entirely below grade or less than 4 feet, 6 inches
above grade.
- CHASE:
- A groove or shaft in a wall provided for accommodation
of pipes, ducts, or conduits.
- CIRCUIT:
- The path of electricity away from, and back to, its
source.
- CODE:
- Refers to the local building codes.
- CONCEALED:
- Rendered inaccessible.
Back to top